Due to the horizontal opening principle and the speed already in the standard the classic. With the adaptation to your exact requirements up to a size of 9000 x 6000 mm unbeatable. It can be used as a rolling door, forklift gate, logistics gate, area gate, sluice gate and much more.
NOVOSPRINT® Syncro – the high-speed door.
Syncro | Syncro L | Syncro XL | ||
---|---|---|---|---|
Door size | Width min./ max. (clear passage width) | 1.000/ 5.300 mm | 2.400/ 5.500 mm | 3.800/ 9.000 mm |
Height min./ max. (clear passage height) | 1.700/ 4.500 mm | 2.100/ 5.100 mm | 2.100/ 6.000 mm | |
Camber requirement min. | 330 mm | 330 mm | 480 mm | |
Space requirement Total depth min./ max. | 420/ 520 mm | -/ 550 mm | 650/ 690 mm | |
Space requirement at side drive side/ non-drive side min. | 350/ 350 mm | 350/ 350 mm | 525/ 525 mm | |
Height of viewing window lower edge/ upper edge in standard | 1.480/ 2.000 mm | 1.480/ 2.000 mm | 1.480/ 2.000 mm | |
Performance data | Designed for up to ... Opening cycles per year | 350.000 | 350.000 | 150.000 |
Short-time duty: Up to ... Opening cycles per hour | 120 | 120 | 60 | |
Opening speed max. | 3,5 m/s | 2,5 m/s | 2,0 m/s | |
Operating forces/ Safe opening according to EN 13241-1 | fulfills | fulfills | fulfills | |
Watertightness according to EN 12425 | Class 0 | Class 0 | Class 0 | |
Resistance to wind load according to EN 12424 up to | Class 2 | Class 2 | Class 2 | |
Airborne sound insulation Rw according to EN ISO 717-1 up to approx. | 7 dB | - | - | |
Thermal resistance Up according to EN 12428 up to | 4,9 W/m²K | 5,9 W/m²K | 5,9 W/m²K | |
Air permeability according to EN 12426 up to | Class 0 | Class 0 | Class 0 | |
Burglary protection according to DIN/ TS 18164 | - | - | - | |
Fire protection class -filling- according to DIN 4102 up to | B1 | B1 | B1 | |
Selectivity number S -filling- (τV/ g-value) | - | - | - | |
Temperature application range Standard min./ max. | 5/ 45 °C | 5/ 45 °C | 5/ 45 °C | |
Radar reflection insulation up to | - | - | - | |
Resistance class -filling- according to DIN 356 up to | - | - | - | |
Mains connection standard | 230 V/ 50 Hz | 230 V/ 50 Hz | 400 V/ 50 Hz | |
Safety devices | OSE as closing edge safety device | fulfills | fulfills | fulfills |
Light grid (integrated) as closing edge safety device | optional | optional | - | |
Opening in case of power failure (with emergency opening lever) | fulfills | fulfills | fulfills | |
Opening automatically in case of power failure | optional | optional | optional | |
Light grid (mounted in front) for contactless reversing | optional | optional | optional | |
Sensor solutions for opening and monitoring | optional | optional | optional | |
Visual or audible warning signals | optional | optional | optional | |
Escape and rescue route approval (TÜV tested) | fulfills | - | - | |
Special solutions | optional | optional | optional |