| Door size | Width min./ max. (clear passage width) | 1.000/ 5.500 mm |
| Height min./ max. (clear passage height) | 1.000/ 8.920 mm | |
| Camber requirement min. | 700 mm | |
| Space requirement Total depth min./ max. | 620/ 1.540 mm | |
| Space requirement at side drive side/ non-drive side min. | 200/ 130 mm | |
| Single door leaf Height approx. | 500 mm | |
| Performance data | Designed for up to ... Opening cycles per year | 50.000 |
| Short-time duty: Up to ... Opening cycles per hour | 20 | |
| Opening speed max. | 40 cm/s | |
| Operating forces/ Safe opening according to EN 13241-1 | fulfills | |
| Watertightness according to EN 12425 | Class 2 | |
| Resistance to wind load according to EN 12424 up to | Class 5 | |
| Airborne sound insulation Rw according to EN ISO 717-1 up to approx. | 21 dB | |
| Thermal resistance Up according to EN 12428 up to | 1,6 W/m²K | |
| Air permeability according to EN 12426 up to | Class 3 | |
| Burglary protection according to DIN/ TS 18164 | RC3 | |
| Fire protection class -filling- according to DIN 4102 up to | B2 | |
| Selectivity number S -filling- (τV/ g-value) | 1,7 | |
| Radar reflection attenuation up to | 20 dB | |
| Resistance class -filling- according to DIN 356 up to | P3A | |
| Mains connection Standard | 1L/N/PE 230V 50Hz | 3L/N/PE 400V 50 Hz | |
| Safety devices | Integrated TÜV certified fall protection | fulfills |
| Mechanical overload protection | fulfills | |
| OSE as closing edge safety device | fulfills | |
| Deferral protection | fulfills | |
| Guide rail closed on three sides | fulfills | |
| Light grid (mounted in front) for contactless reversing | optional | |
| Sensor solutions for opening and monitoring | optional | |
| Visual or audible warning signals | optional | |
| Special solutions | optional |