One size larger and of course as individual as your company. Up to 7.5m wide, the optimal solution to separate your hall from unwanted external influences.
HT60 | HT60XL | ||
---|---|---|---|
Gate size | Width min./ max. (clear passage width) | 1.000/ 7.500 mm | 1.000/ 7.500 mm |
Height min./ max. (clear passage height) | 1.000/ 13.000 mm | 1.000/ 13.000 mm | |
Camber requirement min. | 750 mm | 1.250 mm | |
Space requirement Total depth min./ max. | 1.015/ 1.850 mm | 1.015/ 1.850 mm | |
Space requirement on side drive side/ non-drive side min. | 200/ 200 mm | 200/ 200 mm | |
Single door leaf Height approx. | 500 mm | 1.000 mm | |
Performance data | Designed for up to ... Opening cycles per year | 30.000 | 30.000 |
Short-time duty: Up to ... Opening cycles per hour | 10 | 10 | |
Opening speed max. | 14 cm/s | 14 cm/s | |
Operating forces/ Safe opening according to EN 13241-1 | fulfills | fulfills | |
Watertightness according to EN 12425 | Class 2 | Class 2 | |
Resistance to wind load according to EN 12424 up to | Class 5 | Class 5 | |
Airborne sound insulation Rw according to EN ISO 717-1 up to approx. | 23 dB | 23 dB | |
Thermal resistance Up according to EN 12428 up to | 1,1 W/m²K | 1,1 W/m²K | |
Air permeability according to EN 12426 up to | Class 3 | Class 3 | |
Burglary protection according to DIN/ TS 18164 | RC2 | RC2 | |
Fire protection class -filling- according to DIN 4102 up to | B2 | B2 | |
Selectivity number S -filling- (τV/ g-value) | 1,3 | 1,3 | |
Temperature application range Standard min./ max. | -5/ 40 °C | -5/ 40 °C | |
Radar reflection attenuation up to | - | - | |
Resistance class -filling- according to DIN 356 up to | P3A | P3A | |
Mains connection Standard | 400 V/ 50 Hz | 400 V/ 50 Hz | |
Safety devices | Integrated TÜV certified fall protection | fulfills | fulfills |
Mechanical overload protection | fulfills | fulfills | |
OSE as closing edge safety device | fulfills | fulfills | |
Deferral protection | fulfills | fulfills | |
Guide rail closed on three sides | fulfills | fulfills | |
Light grid (mounted in front) for contactless reversing | optional | optional | |
Sensor solutions for opening and monitoring | optional | optional | |
Visual or audible warning signals | optional | optional | |
Special solutions | optional | optional |