For installation situations where the door is exposed to extreme wind loads, SECTIOLITE doors can be equipped with the Storm option. Depending on the width, the door can withstand wind speeds of up to 220 km/h.
An overview of your benefits:
Door size | Width min./max. (clear passage width) | 2.000/ 6.000 mm |
Height min./ max. (clear passage height) | 2.000/ 5.000 mm | |
Camber requirement min. | 350 mm | |
Space requirement Total depth min./ max. | * | |
Space requirement on side drive side/ non-drive side min. | 300/ 185 mm | |
Single door leaf Height approx. | 250 mm | |
Performance data | Designed for up to ... Opening cycles per year | 100.000 |
Short-time duty: Up to ... Opening cycles per hour | 20 | |
Opening speed max. | 1 m/s | |
Operating forces/ Safe opening according to EN 13241-1 | fulfills | |
Watertightness according to EN 12425 | Class 3 | |
Resistance to wind load according to EN 12424 up to | Class 5 | |
Airborne sound insulation Rw according to EN ISO 717-1 up to approx. | 24 dB | |
Thermal resistance Up according to EN 12428 up to | 0,65 W/m²K | |
Air permeability according to EN 12426 up to | Class 4 | |
Burglary protection according to DIN/ TS 18164 | - | |
Fire protection class -filling- according to DIN 4102 up to | B2 | |
Selectivity number S -filling- (τV/ g-value) | 1,7 | |
Temperature application range Standard min./ max. | -5/ 60 °C | |
Radar reflection attenuation up to | - | |
Resistance class -filling- according to DIN 356 up to | P3A | |
Mains connection Standard | 1L/N/PE 230V 50Hz | 3L/N/PE 400V 50 Hz | |
Safety devices | OSE as closing edge safety device | fulfills |
Leading light barrier as closing edge safety device | - | |
Guide rail closed on three sides | fulfills | |
Integrated safety gear in the drive | fulfills | |
Deferral protection | fulfills | |
Electrically and mechanically bolted anti-lift device | optional | |
Light grid (mounted in front) for contactless reversing | optional | |
Sensor solutions for opening and monitoring | optional | |
Visual or audible warning signals | optional | |
Special solutions | optional |